MRI Spare Parts

Coil for Philips MRI ( Intera 1.5T / Achieva )
No. Description Model Serial number Manufacture
1 Body Coil 459800051892 SHR100214 11/2007
2 Body (2)Coil 452213219858 SHR010177
3 Body (3) Coil 459800051892 SHR100019 5/2007
4 Microscopy Coil Gyroscan 452213181713 300039149 5/2004
   –Microscopy Coil 452213181703 300029572
   –Microscopy Driver 452213181722 300048584 7/2004
5 Pediatric Coil (6ch ??) 452213178003 300056953 10/2004
6 QHC EL_Load Coil (with Anterior SYS Head /Neck) 45221313900 300072319 2/2005
  –Head-Neck Coil 459800051921 001221 7/2016
7 Sense Flex (M) 452213231173 300048572 7/2004
8 Sense Flex (S) 452213231193 300048339 7/2004
9 Sense Head Coil (8ch) 453530057611 2174 8/2011
10 Sense NV Coil (16ch) 452213231082 000470 1/2007
11 Spine Coil 452213219873 300047659 7/2004
12 Spine (2) Coil 452213219873 300044190 6/2004
13 Synergy PV Coil 452213178901 100165 10/2006
Part describtion 12 NC refurb/90
used and tested new
1 Grad amp 271 axis 4522 150 31135 x
Grad amp 271 axis 4522 150 31135 x
Grad amp cap bank 4522 150 34171 x
Grad amp 271 PS 601D 4522 150 31182 x
2 Grad amp 281+ axis 4522 150 39281 x
Grad amp 281+ axis 4522 150 39281 x
Grad amp cap bank positive 4522 150 40841 x
Grad amp cap bank negative 4522 150 40841 x
Grad amp 281+ PS 4522 150 39291 x
3 Rf amp S23 4522 131 45827 x
4 Rf amp S30 Driver Module 4522 150 40471
Rf amp S30 PA Module 4522 150 40461
5 Grad coil TNF 2 Achieva 1.5T 4522 132 1597 x
Body coil 4522 131 7701 x
hybrid box 4522 117 9575. x
6 Grad coil TNF 3 Achieva 1.5T 4522 132 5244. x
Body Coil 4522 131 7701 x
hybrid box 4522 117 9575. x
7 table without covers Intera/Achieva x
8 heat exchanger for grad amp 4522 131 92001 x
9 heat exchanger for grad coil 4522 150 30093 x
10 compressor HC 8E 4522 150 22982 x
11 Flex helium line 10m x
12 PS from the filter box 4522 090 05851 x
13 cable from the PFEi to coil connector 4522 132 58551 x
14 PFEI unit Achieva 1.5T (empty) 4522 131 67512 x
CFINT 3 4522 117 96605 x
MRX 4 4522 137 00393 x
QDD 4522 117 81556 x
T/R Switch 1.5T 4522 117 52057 x
Splitter 4522 137 00331 x
15 PFEI unit Intera (empty rack) 4522 131 6751. x
QDD -board 4522 117 8155. x
Coilint 4522 117 8968. x
T/R switch 4522 117 5205. x
PFINT 4522 117 6412. x
Synco-Int 4522 117 8185. x
16 CDAS rack (empty) 1.5T 4522 150 3426. x
RX2 board 4522 132 6267. x
GRADM 4522 117 9587. x
CLK 4522 117 9587. x
PAT 4522 117 9445. x
BULK int 4535 670 3132. x
TXR 4522 132 6268. x
SBC 4522 150 3425. x
PSU 4522 150 3424 x
FANUNIT 4522 150 3427. x
Temp_humidity Sensor 4522 117 95311 x
17 BDAS rack (empty) 1.5T 4522 130 89003 x
switch mode PSU 4522 131 67063 x
BCPP 4522 117 77175 x
DFEC1P 4522 117 8861 x
SyncoRXA 4522 117 60013 x
Transceiver card 4522 117 91501 x
FANUNIT 4522 131 02854 x
18 Thumb wheel switch 4522 132 06353 x
19 Coils different 12 NC
20 ODU RX 4522 132 13362 x
ODU SC 4522 132 13422 x
ODU ST 4522 132 13442 x
21 XW 8200 Rel 2.5 6GB CDAS 4522 132 64641 x
22 XW 8400 Rel 2.6 6GB CDAS 4522 132 64621 x
23 XW 8600 8GB CDAS 4522 132 76941 x
24 Z400 8GB CDAS 4522 133 15331 x
25 cold head kit 4522 150 22732 x
26 adsorber 4522 150 38241 x
27 Burst disc 4522 150 15021 x
finger sensor 4522 150 33611
Nursecall 4522 104 26452 x
Cable Trap 4522 131 15906 x
Headset NV 4522 132 43163 x
Respiratory sensor 4522 131 17812 x
Respiratory hose 4522 131 22414 x